SmartFusion Modules > Utility Billing > Parameters > UB System File > Hand held > Handheld Types

Recent Updates:
6.236 - changed positions 173-181 to be route number and route sequence (left padded with zeros), if sorting by "Route/Sequence" in handheld settings.

Export File Format

All fields are pad right

Field Length Start End Note
Account Number 6 1 6
Address1 35 7 41
Note 57 42 98
Fill 1 99 99
Meter Serial 15 100 114
Mxu Type 1 115 115
ERT ID 13 116 128
Read Code 1 129 129 "M"
Name 25 130 154
High Percent 9 155 163
Previous Reading 9 164 172 labeled as Current Reading in error
Read Sequence 9 173 181 If sorting by "Read Sequence" in handheld settings, will be filled with Route Sequence, if zero, otherwise will be the Read Sequence of the meter
Route Number 3 173 175 If sorting by "Route/Sequence" in handheld settings, left padded with zeros
Route Sequence 6 176 181 If sorting by "Route/Sequence" in handheld settings, left padded with zeros
Rate Type 1 182 182 "W"
Demand Code 1 183 183
Register ID 10 184 193
Latitude 11 194 204
Longitude 11 205 215
Filler 6 216 221

Import File Format

All fields are pad right

Field Length Start End Note
Account Number 6 1 6
Meter Serial 15 7 21
Filler 15 22 36
Read Code 1 37 37 "M"
New Reading 9 38 46
Reading Month 2 47 48
Reading Day 2 49 50
Note 2 51 52
Register ID 10 53 62
Filler 1 63 63
Latitude 11 64 74
Longitude 11 75 85