SmartFusion Modules > Utility Billing > Utility Billing System Settings > Handheld Setup > Handheld Types
Recent Changes:
6.259 - Initial Creation
Type STARZ
Summary
- Single line per entry
- Upload line length: 155 characters
- Transfer To line length: 286 characters
Upload from Handheld ("I")
| Field |
Length |
Start |
End |
Format |
XML Name |
| Meter Number |
10 |
1 |
10 |
|
MeterSerial |
| Reading Source |
1 |
11 |
11 |
"B" if source is "A" |
ReadCode |
|
|
|
|
"M" if source is not "A" |
| Service Address |
30 |
12 |
41 |
|
Address1 |
| Customer Account |
9 |
42 |
50 |
|
AccountNumber |
| Reading Amount |
15 |
51 |
65 |
-1 if meter is skipped |
NewReading |
| Reading Month |
2 |
66 |
67 |
|
ReadingMonth |
| Reading Day |
2 |
68 |
69 |
|
ReadingDay |
| Message |
11 |
70 |
80 |
|
| Route Number |
2 |
81 |
82 |
|
RouteNumber |
| Read Seq |
6 |
83 |
88 |
|
ReadSequence |
| Sequence Number |
6 |
89 |
94 |
|
READSEQ/ROUTSEQ |
| Line Number |
1 |
95 |
95 |
Starts w/ Zero and Increments |
SERVICEPTID |
|
|
|
|
ICS data starts w/ 1 and increments |
| GIS X Coord |
30 |
96 |
125 |
|
"xxx" |
| GIS Y Coord |
30 |
126 |
155 |
|
"yyy" |
Transfer to Handheld ("O")
| Field |
Length |
Start |
End |
Format |
XML Name |
| Meter Number |
10 |
1 |
10 |
|
MeterSerial |
| Reading Source |
1 |
11 |
11 |
"B" if source is "A" |
ReadCode |
|
|
|
|
"M" if source is not "A" |
| Service Address |
30 |
12 |
41 |
|
Address1 |
| Customer Account |
9 |
42 |
50 |
|
AccountNumber |
| Name |
30 |
51 |
80 |
|
Name |
| "PR" |
2 |
81 |
82 |
if INI Display Previous Reading = Y |
|
|
|
|
else blank |
| Previous Reading |
8 |
83 |
90 |
if INI Display Previous Reading = Y |
PreviousReading |
|
|
|
|
else blank |
| Filler |
1 |
91 |
91 |
|
| "A" |
1 |
92 |
92 |
|
| Customer Account |
9 |
93 |
101 |
|
AccountNumber |
| Route Number |
2 |
102 |
103 |
|
RouteNumber |
| "/" |
1 |
104 |
104 |
|
| Sequence Number |
6 |
105 |
110 |
|
READSEQ/ROUTSEQ |
| Filler |
1 |
111 |
111 |
|
FILL |
| Meter Location |
14 |
112 |
125 |
|
"DEFAULT" |
| High Reading Range |
10 |
126 |
135 |
|
HIGHPCT1 |
| Low Reading Range |
10 |
136 |
145 |
|
LOWPCT1 |
| Meter Notes |
50 |
146 |
195 |
|
MNOTE |
| Route Number |
2 |
196 |
197 |
|
RouteNumber |
| Previous Read Seq |
6 |
198 |
203 |
|
| Sequence Number |
6 |
204 |
209 |
|
READSEQ/ROUTSEQ |
| Line Number |
1 |
210 |
210 |
Starts w/ Zero and Increments |
SERVICEPTID |
|
|
|
|
ICS data starts w/ 1 and increments |
| GIS X Coord |
30 |
211 |
240 |
"xxx" |
| GIS Y Coord |
30 |
241 |
270 |
"yyy" |
| Transponder # |
15 |
271 |
285 |
|
ERTID |
| Transponder Type |
1 |
286 |
286 |
|
SF allows 4 characters |